Go-around — SLI850

MMVR · 01

2026-01-31 12:52 UTC· MMMX MMVR· E190

SLI850 was operating from MMMX to MMVR on 2026-01-31. SkyMeter detected a go-around at General Heriberto Jara International Airport (MMVR) on runway 01 at 12:52 UTC. Trace data at the event: 296 ft AGL, 113 kt GS, 0 fpm vertical. METAR at the time reported 18 kt wind, 7 kt crosswind component, 8,047 m visibility. A go-around is a discontinued landing approach in which the pilot adds power and climbs back to a safe altitude before re-attempting the approach or proceeding to an alternate. It is a routine safety response, not an emergency, and is taught as the standard reaction to any unstable approach. Detection algorithm and known limitations: see SkyMeter methodology.

Pilot review data

  • Runway 01
  • 296 ft AGL at event
  • 113 kt ground speed
  • 0 fpm vertical
  • 18 kt wind
  • 7 kt crosswind component
  • 8,047 m visibility
  • METAR MMVR 241140Z 25002KT 5SM FEW080 24/24 A2993 RMK SLP101 5//// 960 60001 8/060 HZY DSNT CB E RWY WET RTS

Flight context

  • SLI850
  • E190
  • MMMX → MMVR
  • 2026-01-31 12:52 UTC
  • MMVR runway 01

All events on this flight

Go-around 12:52:49 UTC · MMVR runway 01 · 296 ft AGL · 113 kt GS
Go-around 12:52:49 UTC · MMVR runway 01 · 296 ft AGL · 113 kt GS
Go-around 12:52:55 UTC · MMVR runway 01 · 391 ft AGL · 120 kt GS
Go-around 12:52:55 UTC · MMVR runway 01 · 391 ft AGL · 120 kt GS
Go-around 12:52:55 UTC · MMVR runway 01 · 391 ft AGL · 120 kt GS
Go-around 12:52:55 UTC · MMVR runway 01 · 391 ft AGL · 120 kt GS

Automated analysis. Events shown on this page (such as go-around, unstable approach, or runway events) are heuristic classifications produced by algorithms from publicly broadcast ADS-B data. They are intended to surface flights of interest for further review — they are not findings of fact, and they do not determine pilot fault, regulatory compliance, or the cause of any occurrence. Coverage gaps and sensor noise can affect accuracy. Only the relevant civil aviation authority or accident investigation body can make official determinations. How we detect events · Dispute or correct this data

SkyMeter · trace data observed via ADS-B· MMVR